Pompa Vakum

  • P5010 multistage ejector with Pi, Si or Xi COAX® push-in cartridge(s).
  • AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
  • Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
  • Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
  • Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
  • Enhanced blow-off effect thanks to a directed blow-off pipe.
  • Analog vacuum sensor with two digital outputs, 16 pre-set combinations of signal levels to choose from.
  • Digital display with “-kPa” or “-inHg” as unit options.
  • Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
  • Three-color LED status indicators for valves, signal outputs and ES.
 
Tampilkan Lebih Banyak
pt.surrama tridaya mandiri
pt.surrama tridaya mandiri

PT.SURRAMA TRIDAYA MANDIRI

PREMIUM BLUE ONYX 11 Tahun
Citi Square Business Park Blok E No. 6 Jl. Peta Selatan RT 010 RW 001, Kalideres, Jakarta Barat
Indonesia 11840
Jakarta Barat
-
Hubungi Kami

Detail PIAB Compact/Stackable - P5010 AVM 2

PIAB Compact/Stackable -  P5010 AVM 2
Pompa Vakum

  • P5010 multistage ejector with Pi, Si or Xi COAX® push-in cartridge(s).
  • AVM™2, Automatic Vacuum Management, unit with built-in control and monitoring functions.
  • Valves for vacuum on/off, blow-off, blow-off flow control and non-return valve.
  • Option with Normally Closed "fail safe" on/off valve (NC). It changes to an open valve if power is lost and vacuum will be generated. A conventional normally closed on/off valve (NC 2) is also available. It stays closed if electrical power is lost or removed.
  • Option with automatic blow-off (1 sec) reduces number of outputs needed from PLC or I/O box.
  • Enhanced blow-off effect thanks to a directed blow-off pipe.
  • Analog vacuum sensor with two digital outputs, 16 pre-set combinations of signal levels to choose from.
  • Digital display with “-kPa” or “-inHg” as unit options.
  • Integrated energy saving function (ES) that minimizes the air consumption in sealed systems. The ES function can be activated manually or via a signal (signal override).
  • Three-color LED status indicators for valves, signal outputs and ES.
 